Engineered and manufactured in India, Bollard Court is a PUR-coated sport vinyl floor engineered for play — shock absorption and controlled ball rebound underfoot, with a hard-wearing surface that stands up to daily use and cleans easily. Available in 4.5 mm and 7 mm thicknesses across 17 solid colours and wood finishes.
Solid colour range
4.5 mm thickness in 1.8 × 20 mtr. rolls — 36 sq.mtr. / 387.5 sft per roll.
4.5 mm build-up
Eight engineered layers, from the PUR surface coating down to a calcium-free foam backing.
- PUR (UV) coating
- 100% PVC wear layer
- Reinforced layer
- Glass fibre stable layer
- Grid stable layer
- Decompression layer
- 100% PVC two-colour closed cell
- Foam layer (calcium free)
Wood finish range
4.5 mm thickness in 1.8 × 20 mtr. rolls — 36 sq.mtr. / 387.5 sft per roll.
7 mm range
7 mm thickness in 1.8 × 15 mtr. rolls — 27 sq.mtr. / 290.62 sft per roll, with higher shock absorption and ball rebound.
Shades shown are indicative; actual samples may vary slightly.
Test data
| Technical characteristics | Test method | 4.5 mm | 7.0 mm |
|---|---|---|---|
| Construction | |||
| Total weight | — | 3.3 kg | 4.6 kg |
| Surface protection | — | PUR | PUR |
| Width of roll | — | 1.8 mtr | 1.8 mtr |
| Length of roll | — | 15 / 20 mtr | 15 mtr |
| Thickness of wear layer | — | 0.50 mm | 1.20 mm |
| Thickness | — | 4.5 mm | 7.0 mm |
| Technical performance | |||
| Dimensional stability | EN 434 | <0.156 | <0.206 |
| Indentation resistance | EN 1516 / EN 433 | <0.40 | — |
| Flexibility low temperature | EN 435 | Pass | Pass |
| Abrasion resistance | EN 1505470-1 / EN 660 | Pass | Pass |
| Propagation fire | EN 14904 | B1 | B1 |
| Shock absorption | EN 14808 | 25% | 30% |
| Vertical ball rebound | EN 12235 | 95% | 97% |
| Resistance to impact | EN 1517 | 9 | 10 |
| Hygiene clean room test | |||
| Colour fastness to day light | ISO 105B02 | Pass | Pass |
| Slip resistance | DIN 51130 | R-10 | R-10 |
| Castor chair continuous use | EN 425 | Suitable | Suitable |
| Resistance to chemicals | EN 423 | No change | No change |
| Sound absorption | ISO 140 / EN 717 | 18 db | 25 db |
| Friction coefficient | EN 13036-4 | 98 | 98 |
| Wear resistance | — | T | T |